Harga UPS Data Center Emmerich Galaxy Net

4.8/5 (72k reviews)
Stok Tersedia
Download Brosur SKU: GNT-2026
Harga UPS Data Center Galaxy Net - Harga Terbaik

Created to maintain extreme scale productivity.

The Emmerich's Galaxy Net series is one of the most reliable, high-performance three-phase Uninterruptible Power Supply system (UPS) on the market, and provide maximum protection with reliable galvanically isolated power and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems.

  • Online Double Conversion dengan Galvanic Isolation Transformer
  • Kapasitas 10 - 200 kVA (15 Varian)
  • DSP Technology & Parallel Operation up to 4 Units
  • Zero Transfer Time (Inverter to Bypass)
  • Garansi Resmi 2 Tahun
  • Modbus RS-232/RS485 + Optional SNMP
Garansi Resmi
Produk Original
Gratis Ongkir*
After Sales Support

Mengapa Beli dari Kami?

Garansi Resmi 2 Tahun

Full warranty dari pabrikan dengan service center resmi di seluruh Indonesia

Gratis Ongkir & Instalasi*

Free shipping untuk area tertentu dan bantuan instalasi dari teknisi berpengalaman

Konsultasi Gratis

Tim ahli kami siap membantu memilih kapasitas UPS yang tepat untuk kebutuhan data center dan sistem kritikal Anda

Technical Specification

MODEL GNM 10 GNM 20 GNM 30 GNM 40 GNT 10 GNT 15 GNT 20 GNT 30 GNT 40 GNT 60 GNT 80 GNT 100 GNT 120 GNT 160 GNT 200
PHASE (IN/OUT) 3 PHASE / 1 PHASE 3 PHASE / 3 PHASE
CAPACITY 10 KVA / 8 KW 20 KVA / 16 KW 30 KVA / 24 KW 40 KVA / 32 KW 10 KVA / 8 KW 15 KVA / 12 KW 20 KVA / 16 KW 30 KVA / 24 KW 40 KVA / 32 KW 60 KVA / 48 KW 80 KVA / 64 KW 100 KVA / 80 KW 120 KVA / 96 KW 160 KVA / 128 KW 200 KVA / 160 KW
INPUT
Nominal Voltage 3 x 380 VAC/400 VAC
Acceptable Voltage Range 285 VAC ~ 475 VAC 285 VAC ~ 485 VAC
Frequency 50/60 Hz ± 10%
INVERTER
Nominal Voltage 220 VAC/230 VAC/240 VAC (1Ph+N) 3 x 380 VAC/400 VAC (3Ph+N)
Precision Stationary: ±1%
Transitory: ±5% (load variations 100-0-100%)
Frequency 50/60 Hz synchronised ±1%
With mains absent ±0.1 Hz
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) ; <5% (Non-linear Load)
Admissible Overload 110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6~1 (inductive or capacitive)
STATIC BYPASS
Type Solid state
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
SYSTEM
Overall Efficiency Line Mode ≥92% ≥93% ≥94%
Battery Mode ≥92.5% ≥93% ≥94%
ECO Mode Yes (Non-parallel models)
EPO Function Yes
Standard IEC 61000-4-5, IEC 62040-2 EMC/EMI, IEC 62040-1 Safety
BATTERY & CHARGER
Battery Type and Numbers 12VDC x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32 pcs batteries)
Charging Method CC/CV
Charging Current Default 10A; Maximum 40A; 5A @ full load
ENVIRONMENT
Operation Temperature 0–35°C continuous; 40°C 8-hour; 45°C derating to 85%
Operation Humidity 0~90% (non-condensing)
Noise Level Less than 70dB @ 1 Meter
MANAGEMENT
Modbus RS-232/RS485 Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux and MAC
Dry Contacts 6 outputs and 2 inputs
Optional SNMP Power management from SNMP manager and web browser

* The maximum charging current is never higher than 40A. Product design, specification, dimension and colour can be changed anytime without advance notice. Please contact your nearest dealer/store for more information and details

Pertanyaan yang Sering Diajukan

Berapa harga UPS Galaxy Net Emmerich?

Harga UPS Galaxy Net Emmerich bervariasi tergantung kapasitas (10-200 kVA) dan model. Anda bisa mendapatkan harga terbaik dengan berkonsultasi langsung dengan tim sales kami melalui WhatsApp.

Apa keunggulan Galaxy Net dibanding UPS lainnya?

Galaxy Net dilengkapi dengan Galvanic Isolation Transformer bawaan yang mengeliminasi common mode noise dan menghilangkan kebutuhan pemasangan sirkuit khusus. Ini menjadikannya pilihan ideal untuk data center, telekomunikasi, dan sistem medis yang membutuhkan perlindungan daya paling ketat.

Apa perbedaan model GNM dan GNT pada Galaxy Net?

Model GNM (10-40 kVA) memiliki konfigurasi 3 Phase Input / 1 Phase Output. Model GNT (10-200 kVA) memiliki konfigurasi 3 Phase Input / 3 Phase Output, cocok untuk instalasi data center skala besar.

Apakah Galaxy Net mendukung konfigurasi paralel?

Ya, Galaxy Net mendukung operasi paralel hingga 4 unit (opsional), sehingga memungkinkan ekspansi kapasitas dan redundansi N+X sesuai kebutuhan data center Anda.

Bagaimana cara order UPS Galaxy Net?

Anda bisa menghubungi kami melalui WhatsApp atau mengisi form inquiry di website. Tim sales kami akan membantu Anda memilih kapasitas yang tepat dan memberikan penawaran harga terbaik.

Proteksi Maksimal untuk Data Center Anda

Dapatkan penawaran harga terbaik untuk UPS Emmerich Galaxy Net

GET SPECIAL DISCOUNT